eXact iDip® Well Driller Professional Test Kit
Your meter
eXact iDip 525486101
- In stock, ready to ship
Free UK standard delivery. In-stock orders dispatched within 3–5 working days.
Your meter
eXact iDip 525486101
Free UK standard delivery. In-stock orders dispatched within 3–5 working days.
Use eXact iDip 525 with the eXact iDip app and a compatible phone or tablet to organise your water testing.
Connect the photometer and select the exact method for your model. Additional tests may require an in-app purchase.
Save readings against customers and water sources, with location information to help you find them again.
Share test history by email and export results for use in a spreadsheet.
Looking for freshwater aquarium or marine kits? The iDip 570 is a separate model with its own methods and reagents.
Explore eXact iDip 570eXact reagents deliver the test chemistry into your sample. The iDip photometer measures the reaction, with model-specific test instructions and result management in the app.
Connect your iDip in the app, choose the test, then prepare and zero the sample as instructed.
Use the specified eXact reagent and follow its dosing instructions.
Complete the mixing, reaction and countdown steps for your test.
Read the result and use the app to save it against the correct water source.
Reagents, sample preparation and timing vary by test. Some methods need multiple reagents or additional equipment. Follow the current in-app method for your exact 525 or 570 model.
iDip Smart Guide · English PDF · 2022 editioneXact iDip® Smart Photometer · 486101
Use the tests and reagents specified for the eXact iDip 525 photometer. Supplied reagents and app test access are separate, so check both when choosing a package.
| Test | Method range | Reagent code and method |
|---|---|---|
| Total alkalinity | 20–200 ppm |
486641
Method notesFollow the matching in-app alkalinity method. |
| Total bromine | 0.07–17.0 ppm |
486644
Method notesFollow the matching in-app total-bromine method. |
| Chloride | 4–500 ppm |
486757
Method notesThis range is for the standard chloride test, expressed as NaCl (salt). Select the matching in-app method. |
| Chloride | 500–6,700 ppm |
486757
Method notesRequires Mini Dilution Kit II 487202. Select the in-app Chloride High method for meter 486101 and follow its dilution instructions. The range is expressed as NaCl (salt). |
| Chlorine dioxide | 0.06–6.0 ppm |
486633
Method notesFollow the matching in-app chlorine-dioxide method, using both DPD-1 and glycine in the specified sequence. Confirm the current UK contents of product 486633 with ITS Europe. |
| Free chlorine | 0.00–12.0 ppm |
486637
Method notesReadings above 6 ppm require two strips. Follow the in-app free-chlorine procedure. |
| Combined chlorine | 0.00–12.0 ppm |
486638
Method notesRun the 486637 DPD-1 free-chlorine test first. Continue with the same sample as directed by the in-app combined-chlorine procedure. |
| Total chlorine | 0.00–12.0 ppm |
486670
Method notesReadings above 6 ppm require two strips. Follow the in-app total-chlorine procedure. |
| Total chlorine | 1–200 ppm |
486672
Method notesFollow the matching in-app high-range total-chlorine method. |
| Copper | 0.04–8 ppm |
486632
Method notesFollow the matching in-app copper method. |
| Cyanuric acid | 6–120 ppm |
481652-III
Method notesLiquid reagent. Select the in-app cyanuric-acid method for 481652-III; confirm the reagent version before testing. |
| Chromium VI | 0.00–2.00 ppm |
486614
Method notesFollow the matching in-app chromium VI method. |
| Calcium hardness | 20–700 ppm |
486629
Method notesThis range is for the standard calcium method as CaCO3. Salt-pool and marine methods have different ranges. |
| Total hardness | 60–600 ppm |
486656
Method notesCheck total alkalinity first. Above 200 ppm, use conditioner 486666 as directed by the in-app high-range total-hardness method. |
| Total hardness | 1–90 ppm |
486630
Method notesFollow the in-app low-range total-hardness method. If total alkalinity exceeds 200 ppm, ask ITS Europe to confirm the required pretreatment for this method. |
| Hydrogen peroxide | 1–130 ppm |
486648
Method notesFollow the matching in-app hydrogen-peroxide method. |
| Total iron | 0.03–8.00 ppm |
486650
Method notesFollow the matching in-app total-iron method. |
| Manganese | 0.00–2.2 ppm |
486606
Method notesFollow the matching in-app manganese method. |
| Metals | 0.00–1.6 ppm |
486604
Method notesLiquid reagent for a non-specific total +2-valence metals response. It does not identify individual metals or their separate concentrations. Follow the matching in-app method. |
| Nitrate | 0.25–32.0 ppm |
486655
Method notesThis range applies to the freshwater nitrate method, reported as NO3. Use the separate marine method for marine samples. |
| Nitrite | 0.00–4.00 ppm |
486623
Method notesFollow the in-app nitrite method, reported as NO2. |
| Ozone | 0.01–2.00 ppm |
486634
Method notesFollow the matching in-app ozone method. |
| Peracetic acid | 2–590 ppm |
486675
Method notesSelect the in-app peracetic-acid method for 486675. |
| Peracetic acid | 0.05–11 ppm |
486674
Method notesSelect the in-app low-range peracetic-acid method for 486674. |
| pH | 6.4–8.4 pH |
486639-II
Method notesSelect the matching in-app pH-II method. |
| pH | 3.5–6.2 pH |
486624
Method notesSelect the in-app acidic-pH method for 486624. |
| pH | 7.5–10 pH |
486609
Method notesSelect the in-app alkaline-pH method for 486609. |
| Phosphate | 0.08–3.00 ppm |
486814
Method notesFollow the matching in-app phosphate method. |
| Sulphate | 1–270 ppm |
486608
Method notesFollow the matching in-app sulphate method. |
| Sulphide | 0.05–6.6 ppm |
486818
Method notesFollow the matching in-app sulphide method. |
No tests match your search. Try a parameter name or clear the search.
These are documented method working ranges, not accuracy tolerances or recommended water-quality limits. Check the method notes and current in-app instructions. Some tests require multiple reagents or additional equipment.
Choose a starter package or an application kit. Professional kits include a separate pH+ meter with its own calibration and probe-care requirements.
No packages match your search. Try an application name or clear the search.
App-connected photometer with kit options for pools, drinking water, wells, process water and brewing. Check the required reagents and any additional in-app test purchases.
Product code 486101
Product code 486101-KP-K
Product code 486101-KP2-K
Product code 486101-TW-K
Product code 486101-TW2-K
Product code 486101-WD-K
Product code 486101-WD2-K
Product code 486101-PW-K
Product code 486101-PW2-K
Product code 486101-SB-K
Product code 486101-SB3-K
These summaries describe the current UK listings. Check the individual package details and the app tests you need. Some methods use several reagents or a preceding test, so individual reagent capacities should not be added together as a total number of water tests.
The iDip photometer is factory-calibrated for the specified eXact methods. Zero the sample and perform the checks directed by the instructions. A separate pH+ meter in a professional kit has its own calibration requirements.
Read the operating instructionsThe iDip photometer has a two-year manufacturer warranty, subject to its terms, including registration within 30 days of purchase. Other instruments and replaceable probes have their own terms.
Read the manufacturer’s termsGet help choosing a kit, matching a replacement reagent or using your meter. Your product code is included when you contact ITS Europe.
Ask a product specialistIncluded meter: eXact iDip® Smart Photometer. The specifications and resources below refer to this instrument.
| Product code | 486101 |
|---|---|
| Available tests | More than 40 |
| Connectivity | Bluetooth |
| App requirement | Compatible device and eXact iDip app required; additional tests may require in-app purchase |
Brewing · Drinking water · Food & beverage · Industrial water · Pools & spas
Total alkalinity
Product code 486641
For eXact iDip® Smart Photometer
Method note: Follow the matching in-app alkalinity method.
Reagent reference (English PDF)
Total bromine
Product code 486644
For eXact iDip® Smart Photometer
Method note: Follow the matching in-app total-bromine method.
Reagent reference (English PDF)
Chloride
Product code 486757
For eXact iDip® Smart Photometer
Method note: This range is for the standard chloride test, expressed as NaCl (salt). Select the matching in-app method.
Reagent reference (English PDF)
This professional kit pairs the eXact iDip 525 photometer with a separate eXact pH+ meter.
Supplied in a foam-lined carry case. Use the reagents and software for the 525 nm photometer and selected test.
Details:
The included eXact pH+ is a separate electrochemical meter. Its pH, conductivity, TDS, salinity and temperature readings are separate from photometric reagent tests. Follow the calibration and probe-care instructions for the supplied pH+ version.
The eXact iDip app and a compatible smartphone or tablet are required. The app is free to download; additional test software may require in-app purchase. Before ordering, check the current Apple App Store or Google Play listing and confirm the software and reagents for your 525 nm model and selected test.
Follow the eXact iDip app instructions for your 525 nm instrument and selected test, including the sample preparation, reagent, timing and dilution steps. Read the manufacturer's iDip instructions.
Reagent requirements and detection ranges are specific to the selected test and instrument model. Confirm the current 525 nm method before choosing refills. Do not use the other iDip model's range as a substitute.