Your tests. Your records. Connected.

Use eXact iDip 525 with the eXact iDip app and a compatible phone or tablet to organise your water testing.

Choose your tests

Connect the photometer and select the exact method for your model. Additional tests may require an in-app purchase.

Keep your records together

Save readings against customers and water sources, with location information to help you find them again.

Share the results

Share test history by email and export results for use in a spreadsheet.

Looking for freshwater aquarium or marine kits? The iDip 570 is a separate model with its own methods and reagents.

Explore eXact iDip 570

Test chemistry, delivered differently.

eXact reagents deliver the test chemistry into your sample. The iDip photometer measures the reaction, with model-specific test instructions and result management in the app.

Connect and select

Connect your iDip in the app, choose the test, then prepare and zero the sample as instructed.

Add the right reagent

Use the specified eXact reagent and follow its dosing instructions.

Follow the test timing

Complete the mixing, reaction and countdown steps for your test.

Read, save and share

Read the result and use the app to save it against the correct water source.

Reagents, sample preparation and timing vary by test. Some methods need multiple reagents or additional equipment. Follow the current in-app method for your exact 525 or 570 model.

iDip Smart Guide · English PDF · 2022 edition

The right test. The right reagent.

eXact iDip® Smart Photometer · 486101

Use the tests and reagents specified for the eXact iDip 525 photometer. Supplied reagents and app test access are separate, so check both when choosing a package.

TestMethod rangeReagent code and method
Total alkalinity 20–200 ppm 486641
Method notes

Follow the matching in-app alkalinity method.

Total bromine 0.07–17.0 ppm 486644
Method notes

Follow the matching in-app total-bromine method.

Chloride 4–500 ppm 486757
Method notes

This range is for the standard chloride test, expressed as NaCl (salt). Select the matching in-app method.

Chloride 500–6,700 ppm 486757
Method notes

Requires Mini Dilution Kit II 487202. Select the in-app Chloride High method for meter 486101 and follow its dilution instructions. The range is expressed as NaCl (salt).

Chlorine dioxide 0.06–6.0 ppm 486633
Method notes

Follow the matching in-app chlorine-dioxide method, using both DPD-1 and glycine in the specified sequence. Confirm the current UK contents of product 486633 with ITS Europe.

Free chlorine 0.00–12.0 ppm 486637
Method notes

Readings above 6 ppm require two strips. Follow the in-app free-chlorine procedure.

Combined chlorine 0.00–12.0 ppm 486638
Method notes

Run the 486637 DPD-1 free-chlorine test first. Continue with the same sample as directed by the in-app combined-chlorine procedure.

Total chlorine 0.00–12.0 ppm 486670
Method notes

Readings above 6 ppm require two strips. Follow the in-app total-chlorine procedure.

Total chlorine 1–200 ppm 486672
Method notes

Follow the matching in-app high-range total-chlorine method.

Copper 0.04–8 ppm 486632
Method notes

Follow the matching in-app copper method.

Cyanuric acid 6–120 ppm 481652-III
Method notes

Liquid reagent. Select the in-app cyanuric-acid method for 481652-III; confirm the reagent version before testing.

Chromium VI 0.00–2.00 ppm 486614
Method notes

Follow the matching in-app chromium VI method.

Calcium hardness 20–700 ppm 486629
Method notes

This range is for the standard calcium method as CaCO3. Salt-pool and marine methods have different ranges.

Total hardness 60–600 ppm 486656
Method notes

Check total alkalinity first. Above 200 ppm, use conditioner 486666 as directed by the in-app high-range total-hardness method.

Total hardness 1–90 ppm 486630
Method notes

Follow the in-app low-range total-hardness method. If total alkalinity exceeds 200 ppm, ask ITS Europe to confirm the required pretreatment for this method.

Hydrogen peroxide 1–130 ppm 486648
Method notes

Follow the matching in-app hydrogen-peroxide method.

Total iron 0.03–8.00 ppm 486650
Method notes

Follow the matching in-app total-iron method.

Manganese 0.00–2.2 ppm 486606
Method notes

Follow the matching in-app manganese method.

Metals 0.00–1.6 ppm 486604
Method notes

Liquid reagent for a non-specific total +2-valence metals response. It does not identify individual metals or their separate concentrations. Follow the matching in-app method.

Nitrate 0.25–32.0 ppm 486655
Method notes

This range applies to the freshwater nitrate method, reported as NO3. Use the separate marine method for marine samples.

Nitrite 0.00–4.00 ppm 486623
Method notes

Follow the in-app nitrite method, reported as NO2.

Ozone 0.01–2.00 ppm 486634
Method notes

Follow the matching in-app ozone method.

Peracetic acid 2–590 ppm 486675
Method notes

Select the in-app peracetic-acid method for 486675.

Peracetic acid 0.05–11 ppm 486674
Method notes

Select the in-app low-range peracetic-acid method for 486674.

pH 6.4–8.4 pH 486639-II
Method notes

Select the matching in-app pH-II method.

pH 3.5–6.2 pH 486624
Method notes

Select the in-app acidic-pH method for 486624.

pH 7.5–10 pH 486609
Method notes

Select the in-app alkaline-pH method for 486609.

Phosphate 0.08–3.00 ppm 486814
Method notes

Follow the matching in-app phosphate method.

Sulphate 1–270 ppm 486608
Method notes

Follow the matching in-app sulphate method.

Sulphide 0.05–6.6 ppm 486818
Method notes

Follow the matching in-app sulphide method.

These are documented method working ranges, not accuracy tolerances or recommended water-quality limits. Check the method notes and current in-app instructions. Some tests require multiple reagents or additional equipment.

Find your eXact iDip 525 package.

Choose a starter package or an application kit. Professional kits include a separate pH+ meter with its own calibration and probe-care requirements.

eXact iDip 525

Meter model 486101

App-connected photometer with kit options for pools, drinking water, wells, process water and brewing. Check the required reagents and any additional in-app test purchases.

Pool Starter Kit

Product code 486101-KP-K

  • eXact iDip 525 photometer
  • Carry case, cleaning brush and instructions
  • Reagents: total alkalinity, pH, free chlorine (DPD-1), combined/total chlorine (DPD-3), calcium hardness and cyanuric acid

Pool Professional Kit

Product code 486101-KP2-K

  • eXact iDip 525 photometer
  • Separate eXact pH+ meter
  • Carry case, brush, instructions, pH 4 and pH 7 buffers and acrylic verification key
  • Reagents: total alkalinity, pH, free chlorine (DPD-1), combined/total chlorine (DPD-3), calcium hardness and cyanuric acid

Tap Water Kit

Product code 486101-TW-K

  • eXact iDip 525 photometer
  • Carry case, cleaning brush and instructions
  • Reagents: pH, total alkalinity, high-range total hardness, high-range chlorine, free chlorine, total chlorine and metals

Tap Water Professional Kit

Product code 486101-TW2-K

  • eXact iDip 525 photometer
  • Separate eXact pH+ meter
  • Carry case, cleaning brush and instructions
  • Reagents: total alkalinity, high-range total hardness, free chlorine, total chlorine (DPD-4), high-range chlorine and metals

Well Driller Professional Kit

Product code 486101-WD2-K

  • eXact iDip 525 photometer
  • Separate eXact pH+ meter
  • Carry case, brush, instructions and pH 4 and pH 7 buffer pouches
  • Reagents: total iron with reducer, nitrate, total alkalinity and high-range total hardness

Process Water Kit

Product code 486101-PW-K

  • eXact iDip 525 photometer
  • Carry case, cleaning brush and instructions
  • Reagents: pH, high-range chlorine, free chlorine, total chlorine and hydrogen peroxide; glycine preparation reagent

Process Water Professional Kit

Product code 486101-PW2-K

  • eXact iDip 525 photometer
  • Separate eXact pH+ meter
  • Carry case, cleaning brush and instructions
  • Reagents: free chlorine (DPD-1), total chlorine (DPD-4), high-range chlorine and hydrogen peroxide; glycine preparation reagent

Smart Brew Starter Kit

Product code 486101-SB-K

  • eXact iDip 525 photometer
  • Carry case, cleaning brush, instructions and verification key
  • Reagents: pH, total alkalinity, chloride, calcium hardness, high-range total hardness and sulfate

Smart Brew Professional Kit

Product code 486101-SB3-K

  • eXact iDip 525 photometer
  • Separate eXact pH+ meter
  • Carry case, cleaning brush and instructions
  • Reagents: high-range total hardness, calcium hardness, total alkalinity, chloride III and sulfate

These summaries describe the current UK listings. Check the individual package details and the app tests you need. Some methods use several reagents or a preceding test, so individual reagent capacities should not be added together as a total number of water tests.

Practical support for your meter.

Factory-calibrated photometer

The iDip photometer is factory-calibrated for the specified eXact methods. Zero the sample and perform the checks directed by the instructions. A separate pH+ meter in a professional kit has its own calibration requirements.

Read the operating instructions

Two-year photometer warranty

The iDip photometer has a two-year manufacturer warranty, subject to its terms, including registration within 30 days of purchase. Other instruments and replaceable probes have their own terms.

Read the manufacturer’s terms

Help with your next test

Get help choosing a kit, matching a replacement reagent or using your meter. Your product code is included when you contact ITS Europe.

Ask a product specialist

Included meter: eXact iDip® Smart Photometer. The specifications and resources below refer to this instrument.

Technical specifications
Product code486101
Available testsMore than 40
ConnectivityBluetooth
App requirementCompatible device and eXact iDip app required; additional tests may require in-app purchase

Applications

Brewing · Drinking water · Food & beverage · Industrial water · Pools & spas

Manuals and downloads

Reagents for this meter

Find a specific reagent
ITS Europe eXact® Strip Micro Chloride

Chloride

eXact® Strip Micro Chloride

Product code 486757

Range
4–500 ppm
Tests per pack
25

For eXact iDip® Smart Photometer

Method note: This range is for the standard chloride test, expressed as NaCl (salt). Select the matching in-app method.

Reagent reference (English PDF)

£17.39

Description
Description

This professional kit pairs the eXact iDip 525 photometer with a separate eXact pH+ meter.

Supplied in a foam-lined carry case. Use the reagents and software for the 525 nm photometer and selected test.

Details:

  • Standard navy blue plastic carrying case w/ Foam includes.
  • eXact iDip® 525 Photometer.
  • Cleaning brush.
  • Instruction manual.
  • Supplied photometric reagents: 25 tests per method
  • High Range Total Hardness, Calcium Hardness, Total Alkalinity, Chloride III, Sulfate.
  • eXact® pH+ Smart Meter System.
  • Separate pH+ readings: pH, TDS, salinity, conductivity and temperature.

The included eXact pH+ is a separate electrochemical meter. Its pH, conductivity, TDS, salinity and temperature readings are separate from photometric reagent tests. Follow the calibration and probe-care instructions for the supplied pH+ version.

The eXact iDip app and a compatible smartphone or tablet are required. The app is free to download; additional test software may require in-app purchase. Before ordering, check the current Apple App Store or Google Play listing and confirm the software and reagents for your 525 nm model and selected test.

Download on the App Store   Get it on the Google Play
Instructions

Follow the eXact iDip app instructions for your 525 nm instrument and selected test, including the sample preparation, reagent, timing and dilution steps. Read the manufacturer's iDip instructions.

Tests & reagents

Reagent requirements and detection ranges are specific to the selected test and instrument model. Confirm the current 525 nm method before choosing refills. Do not use the other iDip model's range as a substitute.